ABX Minos® 8 parametrs:
20101
Diaton-STE6/STE8-Diluent
20L
20102
Dialyse-STE6/STE8
5L
20104
Dia-Terge
5L
20113
Diaclair
1L
ABX Micros® 8 parametrs:
20101
Diaton-STE6/STE8-Diluent
20L
20112
Dialyse-STE6/STE8
1L
20215
Dia-Cleaner
1L
20113
Diaclair
1L
ABX Minos® 18 parametrs:
20201
Diaton-Diff-LMG-Diluent
20L
20202
Dialyse-Diff-LMG
5L
20104
Dia-Terge
5L
20113
Diaclair
1L
ABX Micros® 18 parametrs:
20201 | Diaton-Diff-LMG-Diluent | 20L |
20212 | Dialyse-Diff-LMG | 1L |
20215 | Dia-Cleaner | 1L |
20113 | Diaclair | 1L |
ABX Micros 45
Fully automated system with great capability provides top performance with daily programmable maintenance. The instrument comes packed with key features such as automatic probe wipe. ABX Micros 45 include; 8 or 16 parameters including 3 part differential and histograms, sampling on closed tube or open tube. The ability to identify samples, programmable high and low limits for patients, and programmable flag sensitivity are other features which make ABX Micros 45 a better choice. It allow a throughput of 45 samples per hour.
Technical:
- Weight: 14 kg.
- Power supply: 90/240 V - 50/60 Hz - 230 VA.
- Dimensions: 42 x 36 x 32(HxWxD) cm .
- Printer: 80 columns dot matrix printer.
- Throughput:
60 samples/hour (on open tube)
55 samples/hour (closed tube)
- Data management: User friendly software.
Smart card reader (optional). RS 232 output.
Mono-directional connection.
- Memory: Last result (with curves) or 78 results (optional smart cards based memory)
- Screen: 2 lines of 40 alphanumerical characters.
- Keyboard: Alphanumeric keyboard.
Barcode reader (optional).
Samples :
- Parameters:
CBC Mode (18 parameters):
WBC, RBC, HGB, HCT, MCV, RDW, MCH, MCHC, PLT, MPV, PCT, PDW, % and#
of LYM, MON and GRA
- CBC & CRP Mode (19 parameters): CBC + CRP
- Graphics:
LMG histogram, RBC, PLT histograms
- Sample-Volume:
CBC mode: 10 µl CBC & CRP mode : 18 µl
- Operating sample mode:
Open tube mode with 4 position tube holder (QC, 500 µl, 3 or 5 ml)
- Identification:
Patient run number
- Flags:
Pathological flags (WBC, RBC, and PLT) and normal limits
The ABX Pentra 400 is an extremely compact Clinical Chemistry benchtop analyser. Its great autonomy with continuous loading provides enhanced productivity in a user friendly enviroment. Innovative features: * 55 on-board parameters with back-up possibility * Up to 420 tests per hour with ISE module * Innovating cassette format * Integrated work station and validation station * Touch screen * Real-time viewing of your activity
ABX Pentra 60 is an elegant and highly compact hematology analyzer that works well in small clinic, POL, and hospitals.
ABX Pentra 60 offers quiet operation and uses focused flow impedance, cytochemistry and light absorbance measurement (DHSS technology). The instrument only uses 53µL of sample volume for the analysis of 5 Diff combining with 5 reagents and 30µL for CBC combining with only 3 reagents.
Product Overview : - Microsampling from whole blood (CBC : 30 µl - DIFF: 53 µl) - Closed tube sampling - Data management on stand-alone PC - Closed tube sampling - Highly compact and cost-effective - MDSS technology - Windows XP Platform Product Features : - MDSS: Microsampling into a pre-heated chamber for highly reproducible results - Measurement methods : Cytochemistry, focused flow impedance. light absorbance and flow cytometry (Eosinofix* and LMNE matrix) - Liquid valves (without pinching): Reliability and increased precision - DHSS*: Flow cytochemistry and sequential measurement (focused flow impedance and absorbance) - No compressor (stepper motor): Reliability, less maintenance and noise