Reflotron Plus System
The Reflotron Plus System performs 15 blood chemistry tests and calculates LDL. It allows you to quickly and accurately monitor chronic conditions like hyperlipidemia, diabetes, hypertension, and anemia. An on-board hard-copy printer eliminates the chance of transcription errors, simplifies record keeping, and gives you an important tool in promoting patient compliance.
Easy to use |
Proven dry chemistry technology, which, depending on the parameter, uses whole blood, serum, or plasma samples. This eliminates the need to mix reagents and provides longer reagent stability. An easy-to-follow videotape is included to simplify training. The System Test Summary Card functions as a reminder for sample type, assay time, appropriate sample tube, and storing conditions, which improves accuracy and reduces waste.
Accurate |
The system auto-calibrates to ensure the highest accuracy. An integral hard-copy printer eliminates the chance of transcription errors.
Reliable |
Uses proven dry chemistry technology that, depending on the paramenter, can utilize whole blood, serum or plasma.
Convenient |
Performs 15 blood chemistry tests and calculates LDL. Eliminates the need to transport samples to the lab. Gives results in about three minutes. Individuals with high risk of vascular disease can be identified immediately.
Profitable |
A reimbursement handbook and consulting are exclusively available to Reflotron System customers via a toll-free hotline.
Support |
Toll-free online technical assistance, troubleshooting, and general information are available seven days a week, 24 hours a day at 1-800-428-4674. Assistance for loaner systems is available as needed.
Compact Size
The ADVIA® 1200 system features a small footprint, which allows it to fit comfortably in any size laboratory.
Standardization as Part of the ADVIA Chemistry Family
The ADVIA 1200 system uses the same reagents, calibrators and controls as the other members of the ADVIA Chemistry family and is based on the same proven reliability.
Meets Workload Needs
With the speed of 1200 tests per hour, the ADVIA 1200 system can keep up with workload requirements whether it is acting as a primary analyzer or as a backup to another system
Microvolume technology:
The ADVIA® 1650 has minimal requirements for sample volume (as low as 2 µL/test), reagent consumption (as low as 80 µL/test) and water consumption (25 L/hour) - thus maximizing management efficiency.
Outstanding productivity:
A rapid, 3-second cycle and system throughput of up to 1650 tests/hour provide powerful high-speed performance, ensure workflow efficiency through peak workloads. Optional universal rack handler facilitates continuous sample feeding for further productivity gains.
Unparalleled walkaway capability:
On-board capacity of 200 samples and 32,000 tests - plus our exclusive Sample Saver Technology for automatic repeat, dilution and reflex testing without operator intervention - optimizes walkaway time, frees you to work on additional tasks.
Expertise in automation:
For 50 years we have been recognized for our innovation - just as clinical chemistry has been recognized as the driver of automation. The tradition continues. The ADVIA 1650 can be integrated with other testing disciplines via the ADVIA WorkCell™ or ADVIA LabCell® automated sample transportation systems.
How can your lab work more efficiently?
Does your current chemistry system simplify workflow? Are you able to maximize operations and minimize interruptions? You need a system with reliable ease of use and simple maintenance. You need an analyzer that increases user satisfaction and reduces user interaction without compromising results.
How do you maximize productivity today and tomorrow?
Can your lab keep up during peak workload times? Is there a slowdown when you need capabilities that require more than just routine chemistry? You need a system with a comprehensive menu and high throughput. So you have the ability to meet all the demands of your lab now and in the future.
How do you ensure total system reliability?
Is your system designed for maximum uptime? Does it provide consistent, high-quality results? You need a solution that incorporates advanced software, methods and systems. You need a trusted partner that delivers every element of reliability, from design and calibration to quality control.
Can your analyzer handle all your chemistry testing during periods of peak workload?
Do you have the speed necessary to keep pace with your expanding demands? You need a platform that offers a rapid, consistent tube processing speed, complemented by unmatched throughput to keep your laboratory at the pinnacle of productivity.
Can you depend on your system’s reliability when you need it most?
You need a chemistry analyzer with maximum uptime—one with hardware demonstrated to
prevent downtime, features that check the integrity of the sample and dependable methods for consistent quality of results.
Do you have the true consolidation power you need?
Is your assay menu as complete as possible? You need a system that includes a comprehensive chemistry assay menu, special chemistry methods, open channels for user-defined applications and a large onboard reagent capacity. You need a system that maintains peak speed regardless of the test mix to give you true consolidation power.
Technical specifications
Instrument Memory |
|
---|---|
|
200 Patient test results, including Operator Identification.
|
|
200 Patient details, including name and/or Patient Identification. |
Interface |
|
---|---|
User:
|
Touch screen display; alphanumeric input; password protection.
|
Computer:
|
Results are sent to a personal computer via a RS-232 serial port using a 9-pin null modem cable. |
Power Requirements |
|
---|---|
|
110V AC +/- 20% 45-65 Hz.
|
|
Battery powered operation (optional) 6 AA non-rechargeable alkaline batteries, not included. |
Dimensions/Weight |
|
---|---|
Depth:
|
10.7 inches
|
Width:
|
6.7 inches
|
Height:
|
6.2 inches
|
Weight:
|
3.65 lb |
Operation |
|
---|---|
Temperature Range:
|
41ºF - 104ºF
|
Humidity Range:
|
20% - 80% Relative Humidity, non-condensing
|
Calibration:
|
Automatic, self-calibrating
|
Technical specifications:
Overview
|
|
---|---|
System Description
|
Point-of-care immunoassay analyzer
|
Quantitative Tests
|
Hemoglobin A1c (whole blood): Range: 2.5% to 14%
|
Test Format
|
Self-contained immunoassay cartridges
|
Test Measurement
|
Automatic, optional transmission
|
Test Method
|
HbA1c and Microalbumin - monoclonal antibody
|
Time to Test Results
|
HbA1c - 6 min, A:C Ratio - 7 min
|
General
|
|
---|---|
Dimensions
|
9.0 (h) x 11.5 (w) x 10.5 (d) in |
Weight
|
3.88 kg (9.0 lbs)
|
Power Requirements
|
100 to 240 VAC; 50/60 Hz
|
Line Leakage Current
|
<0.3 mA in normal condition
|
Maximum Power Input
|
70 VA; 30 watts
|
Ambient Operating
Temperature
|
18°C to 30°C (64°F to 86°F) -
Microalbumin 15°C to 32°C (61°F to 88°F) - HbA1c |
Operating Humidity
|
10 to 90%, relative humidity
|
Safety
|
UL/CUL with CB Scheme, CSA-C22.2, EN60601,
IEC60601, UL60601 |
EMC Emissions/Immunity
|
FCC 47 - Part 15 (Class B), EN60601-1-2 (Class B)
|
Test Handling
|
|
---|---|
Sample Volume
|
HbA1c - 1µL whole blood
|
Sample Preparation
|
No pretreatment; no pipetting required
|
Sample ID/Operator ID Entry
|
Optional; via touch screen or bar code reader
|
Calibration
|
|
---|---|
Calibration
|
Lot-specific calibration card provides automatic calibration |
Onboard Computer
|
|
---|---|
Storage Capacity/Memory
|
4000 patient and/or control records
|
Display
|
Color touch screen with 1/4 VGA resolution
|
Data Export
|
Via USB flash drive to PC
|
Quality Control/Compliance
|
|
---|---|
Flexible QC Scheduling
|
None, Automatic Reminders or Required
|
QC Testing
|
Optional lockout if schedule not followed or QC fails
|
User/Operator Access
|
Restricted, if desired
|
Matching Lab Results/
Reference Method |
Adjustable correlation to reference methods |
Reference Ranges
|
User-definable reference ranges available for HbA1c
|